Home About Us Products Technical Information Applications Distributors Exhibitions Contact Protech
PIRIMID XL2V-WC Series Specification Sheet
PIRIMID XL2V-WC-IRS Series Specification Sheet
     

 

PIRIMID XL2V-WC Series Installation Guide
Ikegami Camera MNL
       

ACCESSORIES

     
  G E N E R A L
The XL2V-WC version of the PIRAMID features an internally mounted 1/3” Super Cube Day/Night Camera. This high performance camera is ideal for surveillance applications and provides super picture quality and high sensitivity with minimum illumination 0.0075 lux /F1.2. The PIRAMID XL2V-WC offers a form C relay output to activate various video switching equipment and is ideal for remote video monitoring applications.

Model SDI-77XL2V-WC is a dual technology sensor combining PROTECH’s proprietary “Stereo Doppler” microwave technology with a dual-element passive infrared sensor. The independent sensor modules are “And Gated” and must activate simultaneously to create an overall sensor alarm.

The XL2V-WC version of PIRAMID has a very broad application range. The key to success is PROTECH’s proprietary dual-channel “Stereo Doppler” microwave portion and its ability to ignore vibration and randomly moving objects. An internal sensitivity switch selects the distance an intruder must move to initiate an alarm. This built-in flexibility affords a high level of security while virtually eliminating nuisance false alarms.

  F E A T U R E S

Day/Night Camera:
Super Cube DSP 1/3” Day/Night Camera is mounted within the sensor housing and provides a field of view that matches the sensor protection pattern of 90 ft. x 50 ft.
Heater
:
24V, 1A heater is mounted near the camera aperture to eliminate condensation and moisture on the viewing window.
Stereo Doppler Microwave Detector
:
Two receiving channels with the ability to eliminate vibration and periodically moving objects as sources of false alarms.
Dual Element Infrared Detector
:
Ignores normal temperature variations yet is very responsive to rapid infrared changes created by an intruder.
Microprocessor Controlled:
Proprietary integrated circuit design provides enhanced digital signal processing for both microwave and passive infrared technologies.
Balanced Temperature Compensation:
Stereo Doppler Microwave and Passive Infrared portions automatically adjust detection parameters to compensate for losses in range that occur at elevated temperatures.
Stereo Doppler Supervision:
A component failure will cause the sensor to lock-in alarm.
Digital Range Control:
Ten-position digital switch adjusts how far the sensor detects (to its maximum range).
Digital Sensitivity Control:
Ten-position digital switch adjusts the amount of movement required to initiate an alarm condition.
Enhanced Bird/Animal Immunity Control:
Two-position switch adjusts the sensor's immunity to birds and small animals.
Master Alarm LED:
Displayed on the face of the unit indicating the alarm relay status.
Analytic LED's:
Alarm and Environmental Caution LED's for both technologies are displayed on the face of the sensor. An internal switch can disable both Master and Analytic LED's.
Walk-Test Sounder
:
Optional audible tester to assist in the walk-test and initial sensor set-up. The XL-Sounder greatly simplifies the installation as it enables walk-testing and adjustment by a single installer.
Swivel Mounting:
180° Horizontal Adjustment 90° Vertical Adjustment
Tamper Proof:
Tamper switch with terminal connection.
All Solid State Relay:
User selectable form C relay output. A Solid State relay is flexible, silent and more reliable than an electromechanical relay.
Metal Housing:
Rugged, weather-proof housing offers maximum protection against RFI and EMI interference.
Weather Shroud:
Metal hood that routes rain away from sensor's face and provides maximum protection from ice, snow, wind and sun loading.

  S P E C I F I C A T I O N S
SENSOR SPECS:  
Input Voltage:
8.5 to 20 V-DC)
Current Consumption:
150mA @ 12vDC (LED’s off)
RF Power Density: 120 uW/cm2 max. at the face of the unit
Heater Current :
500mA @ 24V (AC or DC)
Operating Temperature : -30 F to 130 F | -34 C to 54 C
Operating Humidity : 0 to 100% Relative Humidity
Relay Contact Rating : 0.1A, 50V
Housing Dimensions : 6 .25" L x 8.0" W x 4.75" H
Shroud Dimensions: 10.0" L x 8.5" W x 5.25" H
Microwave Frequency: Factory adjusted to one of
the following frequencies:
10,525 MHz USA
10,587 MHz International
9,900 MHz International
9,470 MHz International
   
CAMERA SPECS:  
Imaging Device: 1/3” Interline Transfer CCD
No. of Effective:
Picture Elements:
Approx. 380,000 pixels, 768(H) x 494(V) Line
Scanning Area: 4.8(H) x 3.6(V) mm
Horizontal Resolution: 520 Lines
Minimum Ill: ACK Off (Color):
F1.2 0.35 lux (30IRE). 0.7 lux (50IRE)
F1.2 0.25 lux (30IRE). 0.5 lux (50IRE)
ACK On (Monochrome):
F1.2 0.15 lux (30IRE). 0.3 lux (50IRE)
F1.0 0.10 lux (30IRE). 0.2 lux (50IRE)
S/N Ratio: 48dB/rms or better
TV System: 2:1 Interlace, NTSC system
Int. Sync System: Crystal lock or Line lock (phase adjustable)
V Sync System: INT: 59.94 Hz
Line Lock: 60 Hz
H Sync System: INT: 15.734 KHz
Line Lock: 15.750 KHz
Video Output: VBS 1.0Vp-p 75 (omega)
White Balance: TTL Method, ATW
Backlight Compensation: On/Off Switchable (BLC)
AES: On/Off Switchable, AES 1:1600
ACK: On/Off Switchable
Auto Iris Function: Video Iris/DC Iris Switchable
Flange Focal Distance
Adjustment Function:
Provided
Lens Mount: CS Mount
Camera Mount: 1/4” -20UNC (top and bottom)
Ambient Operating
Temperature:
-10 – +50 deg.C
Power Supply: AC24V +/- 10% 60Hz/DC 12V
Power Consumption: Approx 3.6W
Input/Putput Connectors:

(1) Video Output: BNC
(2) AC24V/DC 12V: 2-pin Terminal
(3) Lens: 4-pin Connector

External Dimension (WHD): 2.52” x 2.52” x 2.09” (64 x 64 x 53 mm)